Skip to content

Risk Academy, led by the Nexus Consortium · Infrastructure, Energy and Industry · Department of Energy and Resources

Stability, adequacy and flexibility in power systems built on wind, solar and storage

Ubungozi bokushintsha kwamandla nokuhlanganiswa kwegridi

A power system dominated by wind, solar and batteries behaves differently from one built on spinning machines, and the risks change with it.

Map energy transition risk and grid integration on a real placeSee the courses

Illustrative: a wind farm on a ridge with rotors turning and helical wakes, or a solar tower and its heliostat field

01Ububanzi

What the discipline covers

The subtopics its courses and labs teach.

Izifundo
In preparation
Amazinga
In development
Amalabhorethri
In development
  • Inverter-based resources and system inertia
  • Frequency and voltage stability
  • Grid-forming and grid-following inverters
  • Resource adequacy and loss-of-load expectation
  • Flexibility, storage and demand response
  • Transmission planning and interconnection queues
  • Blackouts, restoration and black start
  • Data centre demand growth
  • Supply chain risk for transformers, cables and batteries

02Amamephu

Build a twin of any place

Search any place or open the world; the layers and generators follow energy transition risk and grid integration on the planet map, the globe and in 3D.

Wellington and its harbour: a flat plan of the faculty twin. Terrain 0 to 523 m; 83,815 buildings in the box; 5,085 footprints in the core, 2,796 with an estimated height; Roads 176 km; Rail 99 km; 57 substations; 4 port; 2 airport; 5 hospitals; 8 railway stations; 4 water works; 2 power plants, 202 MW. Contours every 100 metres from the elevation grid; buildings as counts per cell; roads and rail by class; lifeline assets as marks; power plants as marks.
Wellington and its harbour, New Zealand. Flat plan of the same data. The 3D twin opens on devices that can draw it, once its data and code have been checked; the numbers are the same either way.
  • Terrain 0 to 523 m
  • 83,815 buildings in the box
  • 5,085 footprints in the core, 2,796 with an estimated height
  • Roads 176 km
  • Rail 99 km
  • 57 substations
  • 4 port
  • 2 airport
  • 5 hospitals
  • 8 railway stations
  • 4 water works
  • 2 power plants, 202 MW
Credits and dates per layer are listed under the stage. Relief in the twin is exaggerated ×1.5 for legibility.

Drag to move, right drag or Shift with a drag to turn and tilt, Ctrl with the wheel to zoom. Keyboard: arrows move, Shift with arrows turn and tilt, + and – zoom, 0 resets, V steps through the views, Escape clears.

Flat plan of the same data. The 3D twin opens on devices that can draw it, once its data and code have been checked; the numbers are the same either way.

The boundaries, names and designations shown do not imply any judgement on the legal status of any territory, or any endorsement or acceptance of such boundaries. Countries: Natural Earth (public domain).

03The subject

The subject, methods and measures and debates and bodies

The discipline

The field and its scope

For grid planners, system operators, protection and control engineers, market analysts and regulators who need to assess stability, adequacy and flexibility in power systems with high shares of inverter-based generation.

Energy transition risk and grid integration studies what happens to a power system when synchronous generators are replaced by wind, solar and batteries connected through power electronics. Inverters do not provide inertia or short-circuit current unless designed to, so frequency moves faster after a disturbance, voltage control becomes a local problem, and protection schemes designed for synchronous machines may not operate. The field covers frequency and voltage stability, the grid-forming and grid-following controls of inverters, resource adequacy under variable supply, the flexibility from storage and demand, transmission expansion and interconnection queues, restoration and black start without large rotating plant, and the demand growth from data centres and electrification. It serves transmission and distribution operators, generators, equipment manufacturers, market operators and regulators.

The discipline took its current form from the stability classification of the IEEE and CIGRE task forces, extended in 2021 to include converter-driven and resonance stability, and from the incident investigations that have followed inverter tripping events in California, South Australia and Great Britain and the April 2025 Iberian blackout. Its standards are being written now: IEEE 2800 for inverter-based resource interconnection, NERC's reliability guidelines and the grid code revisions of ENTSO-E and national operators.

Measures

Quantities and units

QuantityUnit or scaleWhat to know
System inertia and rate of change of frequency (RoCoF)gigawatt-seconds, and hertz per secondInertia is the kinetic energy stored in synchronous machines; RoCoF after a generation loss is the lost power divided by twice the inertia, scaled by nominal frequency. Operators set RoCoF limits of 0.5 to 2 hertz per second for protection; inertia is estimated from online units and is uncertain where behind-the-meter synchronous load is unknown.
Short-circuit ratio at the point of connectiondimensionless ratio of fault level to plant ratingValues below 3 are considered weak and below 2 very weak for grid-following inverters, which can become unstable. Fault level depends on dispatch and so changes hour by hour.
Loss of load expectation and effective load carrying capabilityhours per year, and megawatts of firm equivalent per megawatt installedELCC of solar and four-hour storage falls as their share rises, which single-year estimates do not show; adequacy results change with the weather years and the correlation of outages assumed.
Curtailmentpercentage of available renewable energy not delivered, and gigawatt-hoursA measure of network and system constraint. Rising curtailment signals insufficient transmission, flexibility or export, but some curtailment is economically efficient.
Interconnection queue volume and timegigawatts waiting, and years from application to operationLawrence Berkeley National Laboratory reported over 2,000 gigawatts in United States queues at the end of 2023 with median times near five years; most queued projects withdraw, so queue volume overstates what will connect.
Black-start capability and restoration timenumber of tested black-start units and hours to restore a defined share of loadRestoration plans assume specific units can start without grid supply; as thermal plant closes, operators are testing batteries and grid-forming inverters for this role, with few real events to validate the plans.

Izindlela

Methods and their limits

Each method is listed with what it assumes and where it fails.

IndlelaAssumesFails when
Electromagnetic transient (EMT) simulationThat inverter controls and network dynamics on the microsecond to millisecond scale can be modelled with manufacturer control models and detailed network representation.When manufacturer models are black boxes or unavailable, when the study region is too small to capture interactions, and when the computational cost limits the number of scenarios.
Phasor-domain (RMS) stability simulationThat the network can be represented by phasors and that electromechanical dynamics dominate, as with synchronous machines.When inverter control interactions occur at frequencies the phasor model cannot represent, which is why several real events were not reproduced in RMS studies.
N-1 and N-1-1 contingency analysis with power flowThat the system must withstand defined outages with voltages and flows inside limits, at the operating points studied.When the operating points that are dangerous, such as high renewable output with low load and few synchronous units online, are not among those studied, and when reactive power reserves are assumed from plants that are offline.
Resource adequacy modelling with chronological dispatchThat hourly or sub-hourly simulation over many weather years with storage state of charge captures the shortfalls a high-renewable system faces.When weather datasets lack the multi-day low-wind cold events, when storage is dispatched with perfect foresight, and when demand electrification changes the load shape in ways the model does not sample.
Grid-forming inverter specification and testingThat inverters can be designed to set voltage and frequency, provide synthetic inertia and ride through faults, and that their performance can be verified in hardware-in-the-loop and field tests.When specifications are not yet settled between operators and vendors, when multiple grid-forming units interact in ways single-unit tests do not reveal, and when the inverter's current limit is reached during a fault.
Event investigation with phasor measurement unitsThat synchronised measurements at high rates across the system allow the sequence of a disturbance to be reconstructed.When PMU coverage is sparse at the distribution level where much inverter capacity sits, and when the data of the plants that tripped are not shared.

Debates

What the field debates

Grid-forming inverters or synchronous condensers for system strength?
Synchronous condenser advocates cite proven physics, no control-interaction risk and the deployments in South Australia and Great Britain that restored fault level. Grid-forming advocates cite the lower cost of control software on batteries already being built, successful trials in Australia and Scotland, and the inability of condensers to provide energy. Operators are procuring both while specifications converge.
Is the main adequacy risk under-building capacity or under-building transmission?
One view holds that interconnection queues and curtailment show that generation is available and that transmission and its permitting are the binding constraint, citing studies of the benefit of interregional transmission during extreme weather. The other holds that firm capacity is the issue, citing NERC assessments of elevated shortfall risk as thermal plant retires faster than replacements with equivalent firmness arrive. Both constraints appear in recent events.
Will data centre load growth be met by the grid or by on-site generation?
Utility planners cite forecasts of load growth of tens of gigawatts in some regions and argue for grid investment and demand flexibility from data centres, which some operators now offer. Developers facing multi-year connection waits are building gas turbines and seeking nuclear supply on site; critics note the emissions and the risk of stranded grid investment if forecasts overshoot, as they have in previous waves.

Bodies and data

Bodies that set practice, and the data they publish

Bodies and standards are named so learners can find and apply their published work; the Academy teaches their use and links to the publisher, and no affiliation is implied.

BodyRole in the field
IEEE Power and Energy SocietyPublishes IEEE 2800 on interconnection of inverter-based resources to transmission systems and IEEE 1547 for distribution.
North American Electric Reliability Corporation (NERC)Issues reliability guidelines and standards on inverter-based resource performance and publishes the disturbance reports that shaped them.
ENTSO-EMaintains the European network codes and investigates incidents, including the expert panel on the 28 April 2025 Iberian blackout.
CIGRE Study Committees C2 and C4Publish technical brochures on system operation and system technical performance, including the 2021 stability classification.
Australian Energy Market Operator (AEMO)Operates a system with among the highest inverter-based shares and publishes engineering frameworks and incident reports widely used elsewhere.
Energy Systems Integration Group (ESIG)A technical association that publishes reports on grid-forming technology, resource adequacy and interconnection practice.
DatasetSteward
Queued Up: interconnection queue dataLawrence Berkeley National Laboratory
ENTSO-E Transparency PlatformENTSO-E
NERC event analysis and disturbance reportsNorth American Electric Reliability Corporation
AEMO NEM data dashboardAustralian Energy Market Operator

04Indlela

From a tripped unit to a frequency nadir: inertia, the rate of change of frequency and the seconds that matter

A sudden loss of generation is a power imbalance; the kinetic energy stored in rotating machines sets how fast frequency falls; the seconds until fast reserve arrives set how far it falls; and whether the nadir stays above the load-shedding threshold is the question operators plan around.

Sources: Milano et al., Foundations and challenges of low-inertia systems (2018); Tielens and Van Hertem, The relevance of inertia in power systems (2016); Bialek, What does the GB power outage on 9 August 2019 tell us about the current state of decarbonised power systems? (2020); Hatziargyriou et al., Definition and classification of power system stability revisited and extended (2021).

05Signature

How energy transition risk and grid integration connects the sectors

Select corners to build a signature, then hover a line to read what each sector gives and receives.

Energy and its partners

Energy gives power for transport and telecoms to infrastructure (0.8), pumping and treatment to water (0.5) and fertiliser, machinery and cold chains to food (0.5).

  • 4Imikhakhakwangu-6
  • 6Ubudlelwanokwangu-15
  • 0.46Ukuhlanganiswaingxenye yesamba

Strongest relations in play

  • Energy → Infrastructure · power for transport and telecoms0.8
  • Water → Energy · cooling water and hydropower0.6
  • Water → Food · irrigation0.8
  • Infrastructure → Water · pipes, dams and treatment works0.6

Teaching values for a typical city-region, not measurements for any place. Coupling is the summed strength of the relations in play, as a share of all fifteen.

06At a glance

At a glance, hub, what is changing now and courses

Igrafu ye-3D

Ifakhalthi Yengqalasizinda, Amandla Nemboni

197 nodes1,275 relations9 views

Explore the 3D graph: Faculty of Infrastructure, Energy and Industry

07Ikhonsoli

How Energy transition risk and grid integration is taught, as a process you can run

Press Play to run this process from this page's own data.

Ubungozi bokushintsha kwamandla nokuhlanganiswa kwegridi

How Energy transition risk and grid integration is taught

5 subjects in scope, 3 key terms, courses in development, 1 lab, in the Energy and Resources department of Infrastructure, Energy and Industry: from the scope to the method and its terms, the courses that teach it, the labs on the twin, the assessment and the record.

  1. 01 Scope

    1. 01

      Inverter-based…

      Start · the discipline

      Inverter-based resources and system inertia

    2. 02

      Frequency and voltage…

      Start · the discipline

      Frequency and voltage stability

    3. 03

      Grid-forming and…

      Start · the discipline

      Grid-forming and grid-following inverters

    4. 04

      Resource adequacy and…

      Start · the discipline

      Resource adequacy and loss-of-load expectation

    5. 05

      Flexibility, storage…

      Start · the discipline

      Flexibility, storage and demand response

  2. 02 Method and terms

    1. 06

      From a tripped unit to…

      Model · the learner

      A sudden loss of generation is a power imbalance; the kinetic energy stored in rotating machines sets how fast frequency falls; the…

    2. 07

      Inverter-based resource

      Record · the discipline

      A generator or storage unit connected through power electronics, such as solar, wind or batteries.

    3. 09

      System inertia

      Record · the discipline

      The kinetic energy stored in rotating machines that slows frequency change after a disturbance.

    4. 11

      Grid-forming inverter

      Record · the discipline

      An inverter that sets voltage and frequency itself, so that it can support a grid with few synchronous machines.

  3. 04 Labs

    1. 08

      Umfanekiso wedijithali

      Exercise · the learner, on the faculty twin

      The method runs on the faculty twin and the admitted map layers.

  4. 05 Assess

    1. 10

      Module checks

      Gate · the course

      Each module ends with a short check against its outcomes.

    2. 12

      Assessed work

      Decision · the learner

      The assessed work that closes a course: a lab record, a case memo or an assignment, reviewed against the rubric.

  5. 06 Record

    1. 13

      Irekhodi lokuphothula

      Outcome · the learner

      The record stacks into the discipline achievement.

    2. 14

      Discipline achievement

      Record · the Academy

      The discipline achievement follows the discipline rule, read from the records.

Energy transition risk and grid integration · Energy and Resources An outline of how the work is designed to run; it does not report the status of any decision or record.

08Umkhuba

Practice, learning and connections

Technology in this area

How technology helps and what risk it brings

AspectIn this area
Technology that helpsGrid automation, storage and forecasting.
Risk technology createsAttacks on control systems, space weather, load growth from AI, hydrogen and storage safety, and advanced nuclear.
  • RAN-311 Energy Sector Risk: Generation, Grids and Transition In preparation
  • RAT-261 OT/ICS and Critical Infrastructure Cyber Resilience In development
  • RAT-262 Space Weather Risk and Degraded Operations In development
  • RAN-367 Climate Technology Risk: Carbon Removal, Hydrogen and Storage In development
  • RAN-368 Advanced Nuclear: SMRs, Fusion, Safety, Security and Safeguards In development

Impumelelo

Achievements in this discipline

  1. Course achievements

    One for each course with this as its primary discipline, earned when you pass the course's assessed activities.

  2. Department: Energy and Resources

    Earn two discipline achievements in the Department of Energy and Resources. In development.

An achievement is a record of the learning completed and assessed here. How recognition works.

Where this is practised

Where the subject is practised

A field platform page on this subject is in development.

Practised in

The two Foundry systems where it is practised

  • FoundryNXS-NET systemGrid stability and restoration are network continuity problems
  • NXS-DSS systemTransition pathways and adequacy are scenario sets

Foundry system pages describe what each system and its rooms are designed to do; the courses teach the methods these systems apply.

Across the ecosystem

Across the ecosystem

The science, platforms and standards this discipline draws on and contributes to across the ecosystem.

Foundations in the STEM Commons

Pages of the ecosystem, cited so learners can follow the field into research, platforms, standards and national practice.

09Bamba iqhaza

Take part in Infrastructure, Energy and Industry

Qala kulokho ongikho.

Izindlela

  • Indlela

    Izikhungo zikazwelonke

    Iminyango kahulumeni, amahhovisi ezibalo nama-ejensi: idesiki likazwelonke nesahluko, nesihlalo emaqenjini okusebenza. Izahluko zikazwelonke

  • Indlela

    Imikhakha nemisebenzi

    Operators, regulators, banks, insurers and professional bodies whose work touches infrastructure, energy and industry. For organisations

  • Indlela

    Ukufunda

    Izifundo nokuzijwayeza, nerekhodi lazo zonke izifundo eziqediwe. Mahhala ukufunda. Ukufunda okuvulekile

  • Indlela

    Amazinga

    Bhala okusalungiswa, buyekeza futhi wamukele izindlela namazinga edatha namaqembu okusebenza. Amaqembu okusebenza

  • Indlela

    Imiphakathi nocwaningo

    Universities, civil society and individual experts: projects, data and review. Write to the Academy

Izimemo ezivulekile

Isimemo esivulekileKufunwaKuvalwa
Isimemo sokusungula sochwepheshe emaqenjini okusebenza CALL-FOUNDING-EXPERTSuchwepheshe, umhleli, usihlalo2026-12-15
Ukuqokwa okuvulekile kwezihlalo ezintathu zochwepheshe abazimele ze-Global Standards Council CALL-GSC-INDilungu lomkhandlu2026-12-01
Ukuqokwa kwamalungu esifunda esikhashana (kusebenza kuphela uma isinqumo sesikhashana sithathwa) CALL-GSC-REGilungu lomkhandlu2026-12-15
Ukubuyekezwa kwezinhlaka zomongo wengozi wegagasi 1 (C1, C2, C3, C4, C8, C10, C11) CALL-REVIEW-WAVE1umnikeli2027-01-31
Ochwepheshe bamazinga ayisisekelo esayensi yengozi: ukungaqiniseki nokulinganiswa kobufakazi, izilinganiso, ukwahlulela kochwepheshe okuhlelekile, ukubekezeleleka, izimo ezeqisayo nezehlakalo ezihlanganisiwe, ingozi eyinhlekelele neyokuphila, izimiso nokulingana, amayunithi nokulinganisa (NRS-C17 kuya ku-NRS-C24) CALL-CORE-SCIENCEuchwepheshe, umhleli, usihlalo2027-01-31
Ababuyekezi abazimele bemindeni ye-atlas yezingozi, abathathu abavela okungenani ezifundeni ezimbili emndenini ngamunye (NHS2-R19), imindeni ehamba phambili kuqala CALL-ATLAS-REVIEWuchwepheshe2027-03-31
Amalungu e-Frontier Safety Review Panel yesikhashana nababuyekezi beqembu elibomvu (ukuphepha kwezinto eziphilayo nokuvikeleka kwazo, ukuphepha nokuvikeleka kwe-AI, ukuvikeleka kwengqalasizinda ebalulekile); izicelo ziphathwa ngokuyimfihlo CALL-FRONTIER-SAFETY-REVIEWuchwepheshe2026-11-30
Ochwepheshe be-ontology, i-metrology, ukuqinisekiswa kwesofthiwe nokuhlolwa kokuhambisana kwerejista yezidingo, ukumelwa komshini kwe-NHS-2, amasethi okuhlola ukuhambisana nohlelo lokuhlola ukuhambisana CALL-CONFORMANCE-ONTOLOGYuchwepheshe, umhleli2027-01-31

Izimemo ezidlule usuku lwazo lokuvala zifihlwa ngokuzenzakalelayo. Zonke izimemo, iziphakamiso nezindlela: izindawo nezimemo ezivulekile.

Amaseli nama-CERT

  1. Qoqa iseli

    Hlanganisa abantu abathathu kuya kwabayisikhombisa abanamakhono ahambisanayo: idatha, ukusebenza enkundleni, inqubomgomo nokuxhumana.

  2. Libhalise

    Write to the team with the cell's name, members, area and region. You receive a reference and a contact. Write to the Academy

  3. Khetha umqulu

    Khetha ukugxila okukodwa: ucwaningo nobufakazi, idatha namamephu, ukubuyekezwa kwamazinga, noma ukulungiselela komphakathi.

  4. Funda ndawonye

    Landela izindlela zokufunda ezabelwana ngazo e-Risk Academy, nokuzijwayeza nerekhodi lazo zonke izifundo eziqediwe. Izinsongo nokuqina

  5. Hola futhi ubike

    Hold regular sessions. Publish what the cell learns through Reports. Bring findings to the working groups. Working groups

  • Gxila njengeThimba Lomphakathi Lokusabela Ezimweni Eziphuthumayo (CERT)

    A CERT prepares its neighbourhood for the hazards it faces. It builds a local hazard profile from this site's map. It trains in household and street preparedness. It learns first aid and light search through recognised local providers, and it runs drills. A CERT works alongside the local emergency services and follows their direction. It never replaces them and is not an emergency service.

I-Index

What a national team or a local community can do on The Global Risks Index (NXS-GRX) today.

  • NXS-GRX

    Your country's profile

    Amaphrofayela engozi avulekile amazwe angu-195, nemithombo namalayisense kuyo yonke inani. Vula Inkomba

  • NXS-GRX

    Lungisa noma uphendule

    Lungisa inani noma uphendule ngezwe lakho. Ushintsho lurekhodwa kanye nomphumela walo. Vula Inkomba

  • NXS-GRX

    Nikela ngedatha

    Nikela ngeqoqo ledatha. Lingena ngesango lelayisense, ubongwa. Vula Inkomba

  • NXS-GRX

    Sebenzisa idatha evulekile

    Izendlalelo, amaphrofayela namathayela nge-API evulekile. Vula Inkomba

10References

Core references and where to begin

Start with Hatziargyriou, then Tielens, then Milano.

  1. Hatziargyriou, N. et al., Definition and classification of power system stability revisited and extended (2021). DOI
  2. Milano, F. et al., Foundations and challenges of low-inertia systems (2018). DOI
  3. Kroposki, B. et al., Achieving a 100% renewable grid: operating electric power systems with extremely high levels of variable renewable energy (2017). DOI
  4. Rocabert, J. et al., Control of power converters in AC microgrids (2012). DOI
  5. Denholm, P. et al., The challenges of achieving a 100% renewable electricity system in the United States (2021). DOI
  6. Tielens, P. and Van Hertem, D., The relevance of inertia in power systems (2016). DOI
  7. Matevosyan, J. et al., Grid-forming inverters: are they the key for high renewable penetration? (2019). DOI
  8. Rand, J. et al., Queued Up: characteristics of power plants seeking transmission interconnection (2024). emp.lbl.gov
  9. Bialek, J., What does the GB power outage on 9 August 2019 tell us about the current state of decarbonised power systems? (2020). DOI

11Imibuzo

Imibuzo, izimpendulo namagama abalulekile

Ukufunda lapha kungamahhala yini?

Yebo. Zonke izinkambo nezinto zokufunda ze-Risk Academy, eholwa yi-Nexus Consortium, zifundwa mahhala, ngesivinini sakho noma neqembu. Ukubamba iqhaza okujwayelekile akunayo inkokhelo; umsebenzi ohlawulelwayo, ukuqeqeshwa emsebenzini nezibonelelo zocwaningo kuyizinhlelo ezihlukile.

Kuyini engikuthola ngokuphothula isifundo?

Irekhodi lokuphothula: isifundo, inguqulo yaso, usuku nokuhlolwe, eliyimfihlo ngokuzenzakalelayo futhi labelwana nguwe. Lihlangana libe yimiphumela yomkhakha, yomnyango neyohlelo. Irekhodi likhomba okufundiwe nokuhlolwe, alisho ukuthi ukhono luqinisekisiwe; akulona ilayisense, isihloko sobuchwepheshe noma isimo somsebenzi.

Idatha nezindawo zivelaphi?

Ifakhalthi ngayinye ifundisa ngamawele endawo yangempela akhiwe ngedatha evulekile; isendlalelo ngasinye siveza umhlinzeki waso, ilayisense nosuku, futhi umphumela ngamunye ku-Academy uveza umthombo wawo. Amamephu nezibalo yizinkombandlela zokufundisa, ayisona isilinganiso sendawo.

How do I take part beyond the courses in energy transition risk and grid integration?

Yakha iseli lekhono labantu abathathu kuya kwabayisikhombisa, funda indlela okwabelwana ngayo, thatha umsebenzi ogadiwe kuma-National Working Groups, noma ulethe iqembu labafundi elivela esikhungweni sakho. Ezinhlanganweni.

Amagama abalulekile

Inverter-based resource
A generator or storage unit connected through power electronics, such as solar, wind or batteries.
System inertia
The kinetic energy stored in rotating machines that slows frequency change after a disturbance.
Grid-forming inverter
An inverter that sets voltage and frequency itself, so that it can support a grid with few synchronous machines.
Loss-of-load expectation
The expected number of hours or days in a period when demand cannot be met.

ImibikoNikela

Nikela ngobufakazi kusuka kuleli khasi.

I-Reports iyincwadi yekota ye-Consortium. Lokho oakwaziyo ngalesi sihloko kungaba ubufakazi, icala noma ukulungisa kuhlelo olulandelayo, kubongwe wena futhi kushicilelwe ngaphansi kwe-CC BY 4.0 lapho kungumsebenzi wakho.

Risk Academy

Ungalokothi uthumele idatha yomuntu siqu, imininingwane ebucayi yengqalasizinda noma noma yini ongenalo ilungelo lokuyabelana ngayo. Umnikelo ubuyekezwa ngaphambi kokusetshenziswa; ukuwuthumela akunikezi ubuqambi noma amalungelo okuhlela, futhi ukusekela akuthengi muphumela.

Ubungozi bokushintsha kwamandla nokuhlanganiswa kwegridi

Prepare with a related course

Open courses in connected disciplines teach the methods this discipline will build on.

Buka ikhathalogi yezifundoBack to Department of Energy and Resources